Entire Session Feedback

Effelsberg (Uwe Bach at Thu Nov 08 09:25:30 2012) Success:
Many of the 1.3cm observations didn't had any gaps for pointing at Effelsberg. Since the Effelsberg beam size is just 35" at 22GHz it is highly recommended to insert gaps of 5-6min every 2-3 hours for pointing checks. Also at 6cm and 3.6cm it would be good to leave such short gaps roughly every 4 hours.

Jodrell_Bank (Alastair Gunn at Mon Nov 12 16:19:19 2012) Minor failures: RECO
During this session our Mk5 recorder being used developed the habit of stopping a recording when a vacant bank loaded with a new pack and was switched on. Hence, there are numerous instances of data loss, particularly around times of bank switches...