EC029A

Session: Oct 2009 (session 3)
Wavelength: 18 cm

Comment


To give feedback on this experiment, click here

Experiment Feedback

Medicina (Andrea Orlati at Fri Nov 6 16:31:49 2009) Minor failures : RECO
Mark5 failed to record scans propably up to 10 UT due to a faulty disk pack. After a quick check the DirList output was not consistent to the recorded scans. we'll investigate the module after the end of the session. Starting from 10 UT we decided to change the module and everything looks fine.

Westerbork (Geert Kuper at Sat Nov 7 21:56:14 2009) Minor failures : RECE RFI
Wb used in phased array mode. RFI at 1610 MHz. RT9 gave no signal, but was included in the adding device.

Onsala (Michael Lindqvist at Sun Nov 8 07:37:02 2009) Minor failures :
Lost first minutes. Operator error forgott to issue mk5relink. Noisediode problem, schedule stopped in order to investigate between 12-13 UTC.

Torun (Kaz Borkowski at Mon Nov 9 09:09:22 2009) Minor failures : RECO
For unknown reason Mk5 stopped recording at about 11:50 UTC. After rebooting the schedule restarted at about 12:30. No other known problems.

Effelsberg (Uwe Bach at Mon Nov 9 11:21:46 2009) Minor failures : RECO
Recorder hang during bank change. Took about 40 minutes from 5 to 5:40 UT to solve.

Shanghai (Bo Xia at Tue Nov 10 08:00:26 2009) Success :

Noto (P. Cassaro at Mon Nov 30 09:58:23 2009) Minor failures : TSYS
Tsys missing from the start to 9:34 UT

Jodrell_Bank (Alastair Gunn at Thu Dec 3 11:59:48 2009) Success :
The Lovell Telescope was used (Jb1). No known problems.