EC020B
Session: May 2003 (session 2)
Wavelength: 18 cm
Comment
To give feedback on this experiment, click
here
Experiment Feedback
Noto (P. Cassaro at Tue May 27 12:17:01 2003) Minor failures : RFI
Torun (K.Borkowski at Wed May 28 06:33:57 2003) Success :
No known problems.
Medicina (A. Maccaferri at Wed May 28 06:46:59 2003) Minor failures : RECO
From start to 16:06 second tape head was disconnected,
so no record until that in these tape track.
Lost scans from 27 may 9:50 to 10:33.
Onsala (Michael Lindqvist at Wed May 28 07:07:44 2003) Success :
No known problems.
Effelsberg (A. Kraus at Wed May 28 08:01:24 2003) Minor failures : RFI
Noto (P. Cassaro at Fri May 30 09:13:44 2003) Minor failures : RECO RFI
Severe RFI in the band.
Scan from 140 to 151 losts due to lost of vacuum of the
recorder.
Please ignore the previous feedback of Noto (TOO early!)
Jodrell_Bank (Alastair Gunn at Wed Jun 18 11:30:00 2003) Minor failures :
LO setting may have been wrong for first 40 minutes due to
a power glitch. Tape lost vaccuum at 23:45, back on for 23:56
pass. Vacuum lost again at 00:45, not recovered until next
tape change (37 minutes). Source 10173+0828 was not observed
due to error in MERLIN schedule.
Cambridge (Alastair Gunn at Wed Jun 18 11:30:50 2003) Minor failures :
source 10173+0828 not observed due to error in MERLIN schedule. No
other known problems.
Westerbork (foley at Mon Jul 7 15:23:28 2003) Failure :
observations before 07:03 lost with restarting systems
after power failure
Westerbork (foley at Mon Jul 7 15:25:08 2003) Failure : RECO PHAS
observations after 07:03 headstack 2 not connected
until 15:59 (not noticed after power off) Only stack1 recording
Westerbork (foley at Mon Jul 7 15:25:31 2003) Minor failures : RECO PHAS
RTB unreliable. Used 13 telescopes in the array